MV NORTHERN AURORA

UTC

13:24:06

Vardøy Field · Block 24/6 · North Sea

Power & Machinery

Diesel-electric plant, thruster demand and auxiliary systems with predictive blackout modelling.

DP GREEN — Autopos Active

Generation

Generator load sharing

DG1

Online

2,380kW

Load

68%

41,250 running hours

DG2

Online

2,485kW

Load

71%

39,810 running hours

DG3

Online

2,240kW

Load

64%

44,120 running hours

DG4

Standby

0kW

Load

0%

28,640 running hours

Reserve

Plant headroom

34%

Power margin

2.4%

Blackout risk

Auxiliaries

Battery & hydraulics

Battery / UPS state of charge

91%

Emergency switchboard backed

Hydraulic loop A pressure

168.0 bar

Nominal band 160–185 bar

Hydraulic loop B pressure

118.0 bar

Below minimum — pump 2B seal degradation

Consumers

Thruster demand

Bow Tunnel 1

44%

625 / 1420 kW

Bow Tunnel 2

81%

1604 / 1980 kW

Bow Retract Azi

38%

448 / 1180 kW

Stern Azi Port

57%

1288 / 2260 kW

Stern Azi Stbd

52%

1097 / 2110 kW

Stern Tunnel

29%

249 / 860 kW

Trend · 40 min

Power margin

Trend · 40 min

Load vs margin